Application of Aerogel Thermal Insulation Coating System for External Wall Insulation of New Residential Area
Release time:
2024-07-08
Customer Profile:
Place of use: Shanxi
Construction equipment/pipeline: exterior wall of residential building
Customer requirements: improve clean and beautiful, significantly reduce building energy consumption.
Use of products and programs:
2mm thickness YRY-100 medium coating +0.2mm thickness YRY-101 reflective thermal insulation coating
Working conditions:
Indoor temperature before heat preservation: up to 45 ℃
Specific construction scheme:
Two types of coatings are used without gas putty spraying machine, construction efficiency is high.
Conclusion:
The average indoor temperature difference before and after construction is 3.5-4.5 ℃, and the energy saving effect is obvious.
Construction pictures:

Household Investigation Report on Thermal Insulation Effect of Aerogel Coating System
Our company organized personnel to measure the entrance temperature of buildings 3 and 9 in the residential area. The two buildings have similar structures, the same year of construction, about 30 meters apart from front to back, belong to the same residential area and use the same heating pipe network. The heating situation is basically the same, with great comparability. The comparison is summarized as follows:

We specially chose the residents close to the east and west gables and on the same floor to use the same indoor thermometer to measure the entry temperature. Through data comparison, we know that the temperature of the residents who have made aerogel insulation is 4 ℃, 3.5 ℃ and 4.5 ℃ higher than that of the residents who have not made any insulation.
In addition, I learned from the understanding of the residents that the indoor somatosensory temperature has increased significantly after the building is insulated, and the problem of damp balcony walls has also been greatly improved.